Features
         Small size, compact structure, aesthetic appearance
         Water-cooled, easy to use
         High stability and reliability
         Proprietary driver for alternative
      Applications
         Pump laser for DPSSL
         Laser marking, laser cutting and other industry applications
         Laser system for medical
         Defense
  Specifications
Type NRS-Q2400 NRS-Q5000 NRS-Q6000 NRS-Q10000 Units
Optical (Tc=20¡æ)
Peak Wave
1064
1064
1064
1064
nm
Pulse Width
50-250
50-250
50-250
50-250
¦Ìs
Operating Frequency
¡Ü1000
¡Ü1000
¡Ü1000
¡Ü1000
Hz
Single Pulse Energy
£¾220
£¾220
£¾220
£¾220
mJ
YAG Center Height
40
40
50
50
mm
YAG Size
¦µ3¡Á67
¦µ5¡Á90
¦µ6.35¡Á120
¦µ6.35¡Á150
mm
YAG Terminal
Flat/AR
Flat/AR
Flat/AR
Flat/AR
-
Electrical (Tc=20¡æ)
Threshold Current
<40
<40
<40
<40
A
Peak Current
¡Ü200
¡Ü200
¡Ü200
¡Ü200
A
Working Voltage
<30
<60
<70
<120
A
Structural (Tc=20¡æ)
Size(L*W*H)
78.2¡Á95¡Á65
102¡Á115¡Á87
133¡Á116¡Á87
160¡Á116¡Á90
mm3
Weight
¡Ü1.0
¡Ü1.5
¡Ü2.0
¡Ü3.0
Kg
Absolute Maximum Ratings
Operation Temp. To
10¡«30
10¡«30
10¡«30
10¡«30
¡æ
Storage Temp. Tstg
-20¡«70
-20¡«70
-20¡«70
-20¡«70
¡æ
Cooling Style
Pure Water
Pure Water
Pure Water
Pure Water
-
Cooling Water Temp.
20 ~ 25
20 ~ 25
20 ~ 25
20 ~ 25
¡æ
Cooling Water Flow
¡Ý6
¡Ý10
¡Ý12
¡Ý16
L/min
Cooling Water Pressure
¡Ü3
¡Ü3
¡Ü3
¡Ü3
Kg/cm2
Cooling Water Capacity
¡Ý1.5
¡Ý3.6
¡Ý4.0
¡Ý6.5
KW
The Specifications refer to:  
      NRS-Q2400/Q5000/Q6000/Q10000
    Notes: Newraysing may make changes to specifications and product descriptions at any time without notice. Other output power are available, please contact with us.
  Ordering Information
CopyRight: Beijing Newraysing Laser Technology Co., Ltd.